Solar panels cut the energy our packing houses draw

Fresh Del Monte grows, packs and ships fresh produce for customers in more than 90 countries. The work is visible in the fields, but it is engineered in the buildings: the packing houses where fruit is cooled, graded, boxed and loaded onto reefers. In Australia, that network includes ripening and distribution operations that restock shelves in Melbourne, Brisbane and Sydney, and the same energy standards apply to our packhouses in Central and South America, Kenya and the Philippines.

Those buildings are among the most electricity-hungry parts of the chain. Banana ripening rooms hold narrow temperature bands for days, pineapple lines run pre-cooling and hydro-cooling, and compressors, fans, conveyors, lighting and carton equipment share the same supply. Every kilowatt saved there counts twice: on the bill and in the emissions attached to each tonne we sell.

Roof-mounted photovoltaic panels have proved the quickest lever we have found. A packhouse roof is broad, flat and mostly clear of shade, and its working day already sits in the middle of the day, when the sun delivers most. The arrays therefore feed machinery that is already running rather than competing with it.

What follows covers how much of our consumption the panels actually supply, how we verify the figures, what they cannot fix, and how the result sits against Australian electricity prices, market rules and the legislation that shapes commercial energy use.

What solar changes inside a working packing house

Before the arrays went up, the load curve was predictable in a way that frustrated our energy managers. Refrigeration never stops: green banana rooms sit near 13 degrees Celsius for transport, ripening rooms climb towards 14 to 18 degrees under ethylene, and chilled water loops keep pulp temperatures even. Around that baseline come start-up peaks before dawn and a surge as graders begin.

Generation follows a similar clock. Panels deliver their best output between about 9.30 am and 3 pm, and in a good Queensland summer a site near Cairns or Tully can receive more than 1,000 kWh per square metre annually. That window overlaps the grading line, the wash-down and pre-cooling shift, the carton conveyors, and the cooling load when outside temperatures push towards 35 degrees.

The result is not a flat percentage. Roof area, tilt, shading from neighbouring buildings and the space we must keep clear of condensers and vents all set the ceiling. On a 12,000 square metre roof an array of around 500 to 600 kWp is realistic, and metering at our reference packhouse shows it supplying roughly a third of annual consumption, with most of that used on site.

Reading the meters before and after the installation

Claims about solar are easy to make and hard to prove, so we treat every installation as a measurement project. Fifteen-minute interval meters sit on the main incomer and on the major circuits: refrigeration plant, cooling water, packing line, lighting and auxiliaries. We compare the twelve months before commissioning with the twelve months after, then adjust for tonnes packed, degree days and other changes such as LED upgrades.

Adjusting matters more than the headline. A packhouse that packed 8 per cent more fruit in the second summer shows a bigger bill even if every circuit improved, and a cloudy season in the comparison period flatters the array. We also separate what the panels made, what the site used directly, what spilled to the grid, and what storage carried into the evening peak.

Our wider reporting on water, waste, energy and community programmes sits on https://freshdelmontecsr.com/, where the targets behind these numbers are set out and updated.

Fitting the output to Australia's electricity market

Australia is an unusual place to run a behind-the-meter solar programme. Around a third of households now have rooftop solar, and the habits that come with it have shifted demand: washing machines, dishwashers and pool pumps moved to the middle of the day, and in South Australia and Tasmania wholesale prices can turn negative when the midday fleet outgrows the network. A packhouse is a larger version of that household, except it cannot simply switch off when the price falls.

Policy rewards the right behaviour. The Renewable Energy Target of 43 per cent by 2030 keeps the build-out moving, the Safeguard Mechanism pushes large emitters to cut their own intensity, and the National Greenhouse and Energy Reporting scheme sets the reporting rules for our Australian sites. State schemes such as Victoria's Solar Homes programme, and the feed-in tariffs retailers offer households, steadily shift the value of exported surplus from a fixed credit towards an hourly market price.

Our response is to design for the evening rather than the midday. Panels are sized to serve daytime load first, a battery carries surplus into the 5 pm to 8 pm window when prices peak and the network is tightest, and where the site has a large chilled-water tank, thermal storage shifts cooling hours without touching the batteries. We keep export as an option, but we do not build a business case on prices we cannot control.

From kilowatt hours to a credible claim

Energy data only becomes credible when it meets an accounting standard. Our Australian sites report under the National Greenhouse and Energy Reporting scheme and align with the GHG Protocol, so we calculate both location-based and market-based Scope 2 emissions and publish the market-based figure against our climate targets. Panels cut the electricity we buy; for the share we still buy, we purchase certified renewable instruments rather than claim reductions we have not made.

The programme reaches beyond our own fences. Supporting smallholder growers to meet deforestation-free standards is a long-term commitment, and our work with producers on Rainforest Alliance transition support sets out how training, financing and audit costs are handled across several seasons, because a certification label a grower cannot sustain is worth very little.

Verification is the part that keeps the claim honest. Every installation is signed off by an accredited installer, connected under the national standards for grid-connected distributed generation, and monitored remotely, so that underperformance, shading or panel degradation is caught in the first quarter rather than the first year.

What changed in practice

Solar performs best where the work schedule already matches the sun, and it performs poorly where the load is unavoidable.

Where the panels helped most:

  • Grading, wash-down and pre-cooling scheduled for late morning and early afternoon
  • Compressor plant running at steady load rather than cycling through start-up
  • Daytime packing lines and lighting on the roof-side bays
  • Cold-store doors opened less often during the hottest hours

What the panels could not fix:

  • Refrigeration running through the night, when the array produces nothing
  • The 5 pm to 8 pm demand window without a battery or thermal store
  • Compressor efficiency losses in humid, tropical conditions
  • Electricity used by reefers and long-haul shipping, far from any roof

The figures below summarise a full year of operation at our reference packhouse, with an array sized at 560 kWp.

Measure Before installation After installation Why it matters
Grid electricity purchased 3.1 million kWh a year 2.05 million kWh a year Direct cut in purchased power
Share of consumption generated on site none 33% Depends on matching load to daylight
Peak demand in the 5–7 pm window 640 kW 610 kW Little change without storage
Energy cost per tonne packed A$214 A$158 Lower unit cost on the same output
Scope 2 emissions 1,480 tCO2e a year 980 tCO2e a year Reported under NGER and the GHG Protocol

Energy savings are one part of a wider commitment to keeping products in use for longer and sending less to landfill, and the same principle shapes the community work we fund. In Italy, one partner runs a garment repair course that teaches people to mend and re-wear clothing rather than replace it, keeping textiles out of the waste stream. It is small next to a global operation, but it is the same rule we apply to our own packaging: reuse first, recover second, dispose last.

Two cautions keep us honest: the array only pays when the plant beneath it is efficient, and every number moves with the crop, the climate and the price of electricity. That is why we publish the method alongside the result, and why the interval meters stay in place long after the commissioning team leaves the site.

The next step is fixed: by the end of the 2026 packing season we will extend interval metering to our Australian ripening and distribution sites in Brisbane and Melbourne, so the same before-and-after method can be applied to facilities that still rely on monthly invoices alone.